Sign In | Join Free | My china-telecommunications.com
China TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO., LTD logo
TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO., LTD
TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO.,LTD ESTEL(GUANGDONG) TECHNOLOGY CO., LTD We are the professoinal supplier of outdoor telecom cabinet, air conditioner, heat exchanger, and telecom
Verified Supplier

5 Years

Home > Outdoor Telecom Cabinet >

1300mm Height 20U IP55 Outdoor Telecom Cabinet Without Air Conditioner

TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO., LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

1300mm Height 20U IP55 Outdoor Telecom Cabinet Without Air Conditioner

  • 1
  • 2
  • 3

Brand Name : ESTEL

Model Number : ET7272130-203-6

Certification : ISO9001, CE, RoHs

Place of Origin : China

MOQ : 1 Set

Price : Negotiation

Payment Terms : L/C, Western Union, T/T

Supply Ability : 5000 pcs/month

Delivery Time : 3-4 weeks

Packaging Details : Wooden Case

Dimension : 720×720×1300mm

19” mounting rack : include

Material : Galvanized sheet,single wall

Thickness : 1.5mm

Cooling method : 220AC air conditioner cooling system

Color : RAL7035

Contact Now

1. Outdoor Electrical Cabinet Description

This series cabinet is 1300mm High and 720mm Wide and 720mm Deep. For those who need more than just standard cabinet, this series can also offer a truly the security of customized solution with lots of available options, providing a climate-controlled environment for any electronic equipment, electrical load panels and cable entry solutions. It provides a secure,climate controlled environment for any electronic equipment.

2. Outdoor Electrical Cabinet Structure

Dimension:720×720×1300mm

The cabinet includes 19” mounting rack from top to down, without battery tray

The cabinet is made of galvanized steel, single wall, thickness: 1.5mm, without thermal insulation

3. Outdoor Electrical Cabinet Features

· High reliability, maintenance-free, fast assembly, suitable for harsh environment

· High integration, small footprint, short construction period, reduce the construction cost

· Improved thermal design, efficient energy saving, effectively extending the battery life

· Dynamic environment monitoring system, full alarm signal detection, real-time alarm information reported

· Outdoor cabinet suitable for a variety of outdoor environments.

4. Cabinet Parameters

Cabinet Outdoor telecom cabinet
Material Galvanized sheet,single wall.
Doors 1 Front door
Door lock Anti-theft door lock
Cable inlet Cable entry holes are at the bottom of the cabinet
Heat insulation Optional
installation 19” rack
Thickness panel adopt 1.5mm
Dimension 1300H*720W*720D mm
Cooling method 220AC air conditioner cooling system
Surface treatment

Painting,plasma electrostatic painting,hot galvanized,powder coating,

polishing,brushing,etc.

Mounting method Floor mounting type
Optional accessories The door sensor, water sensor, smoke sensor, temperature and humidity sensor
Security design Embedded door, embedded hinges, 3-point security lock
IP degree IP55
Color RAL7035
Package Wooden case with pallets
Working Temperature -20~+55ºC
Storage Temperature -40~+65ºC

5.Technical Specs

(1) Applicable environment conditions:

Operating temperature: -40°C ~ + 55°C

Storage temperature: -50°C ~ + 70°C

Transport temperature: -50°C ~ + 70°C

Relative humidity (RH): 5%~99%

Air pressure: 62kPa ~ 101kPa (similar to 0m ~ 5000m altitude)

(2) Material: good quality galvanized steel

(3) Surface treatment: powder-coat paint, outdoor polyester light gray RAL 7035 coating

(4) Ingress protection: IP55

(5) Flame retardance: comply with GB5169.7 test A

(6) Insulation resistance: the insulation resistance between grounding devices and cabinet body parts is not lower than 2×104M/500V(DC).

(7) Withstand voltage: the withstand voltage between grounding devices and cabinet body parts is not lower than 3000V(DC)/1min.

6.Power system connections

AC input cable connections The connectors for AC input cable are two-core AC input sockets on the front panel of system. The AC cable can be directly inserted to the connector.

Connection of DC load cables The terminals for load connection of the system are LOAD1-, LOAD2-, totally 2PIN, locating on the front panel of the system. The cable can be directly inserted into the terminal.

7.Cabinet inside Rack

1300mm Height 20U IP55 Outdoor Telecom Cabinet Without Air Conditioner

8.Cabinet Picture

1300mm Height 20U IP55 Outdoor Telecom Cabinet Without Air Conditioner

9.Packing :

1300mm Height 20U IP55 Outdoor Telecom Cabinet Without Air Conditioner


Product Tags:

IP55 Outdoor Telecom Cabinet

      

20U Outdoor Telecom Cabinet

      

1300mm telecom street cabinets

      
Quality 1300mm Height 20U IP55 Outdoor Telecom Cabinet Without Air Conditioner for sale

1300mm Height 20U IP55 Outdoor Telecom Cabinet Without Air Conditioner Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO., LTD
*Subject:
*Message:
Characters Remaining: (0/3000)